{"id":618,"date":"2026-09-29T07:12:31","date_gmt":"2026-09-28T23:12:31","guid":{"rendered":"https:\/\/www.aimoli2016.cn\/?p=618"},"modified":"2026-09-29T07:12:32","modified_gmt":"2026-09-28T23:12:32","slug":"common-questions-regarding-well-purging-before-groundwater-sampling","status":"publish","type":"post","link":"http:\/\/www.aimoli2016.cn\/?p=618","title":{"rendered":"Common questions regarding well purging before groundwater sampling"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Q: Is well purging mandatory for field sampling?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A: Yes. HJ 1019\u20142019 requires purging the well until water quality parameters stabilize or a specified volume of water is removed; additionally, disturbances such as air-lifting or aeration within the well must be avoided.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Q: Should bailers be phased out?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A: No. Standards still retain the bailer as an option for shallow-water-table or small-diameter monitoring wells\u2014it is inexpensive, lightweight, and depth-unrestricted. However, it is sensitive to operator technique and prone to significant VOC loss; caution is advised when using it for projects where VOCs are the primary target.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Q: Why are sampling flow rate requirements stricter than those for purging?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A: Purging rates range from 100 to 500 mL\/min, whereas sampling rates generally should not exceed 100 mL\/min (with a maximum of 500 mL\/min) per HJ 1019\u20142019. The sampling phase directly determines sample quality; changes in dissolved oxygen or VOC loss caused by disturbance cannot be rectified once the sample reaches the laboratory.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Q: Can it replace a low-flow bladder pump?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A: They are not equivalent. <a href=\"https:\/\/www.aimoli2016.cn\/?p=237\">Bladder pumps<\/a> utilize a power source for continuous pumping to achieve low-disturbance sampling. In contrast, the <a href=\"https:\/\/www.aimoli2016.cn\/?p=64\">AML917<\/a> is a manual, static, discrete-depth sampler that fills via hydrostatic pressure and is retrieved after a single sampling event. Their operational methods, continuity, and applicable scenarios differ.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Q: When is well purging considered complete?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A: According to HJ 1019\u20142019, purging can conclude when at least three of the following parameters\u2014pH (\u00b10.1), temperature (\u00b10.5\u00b0C), electrical conductivity (\u00b110%), and turbidity (\u226410 NTU)\u2014remain stable across three consecutive measurements.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Q: How is sampling depth accuracy ensured?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A: The steel cable features integrated depth markings, allowing for positioning based on the target stratum reading prior to deployment. For stratified sampling and sampling from thin aquifers, this level of precision is more critical than portability.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"934\" height=\"1024\" src=\"http:\/\/www.aimoli2016.cn\/wp-content\/uploads\/2026\/07\/AIMOLI-Groundwater-Sampling-Equipment-934x1024.png\" alt=\"AIMOLI Groundwater Sampling Equipment\" class=\"wp-image-346\" srcset=\"http:\/\/www.aimoli2016.cn\/wp-content\/uploads\/2026\/07\/AIMOLI-Groundwater-Sampling-Equipment-934x1024.png 934w, http:\/\/www.aimoli2016.cn\/wp-content\/uploads\/2026\/07\/AIMOLI-Groundwater-Sampling-Equipment-274x300.png 274w, http:\/\/www.aimoli2016.cn\/wp-content\/uploads\/2026\/07\/AIMOLI-Groundwater-Sampling-Equipment-768x842.png 768w, http:\/\/www.aimoli2016.cn\/wp-content\/uploads\/2026\/07\/AIMOLI-Groundwater-Sampling-Equipment.png 1198w\" sizes=\"auto, (max-width: 934px) 100vw, 934px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"576\" height=\"1024\" src=\"http:\/\/www.aimoli2016.cn\/wp-content\/uploads\/2026\/06\/ChatGPT-Image-2026\u5e746\u670824\u65e5-22_16_25-576x1024.png\" alt=\"AIMOLI\" class=\"wp-image-185\" srcset=\"http:\/\/www.aimoli2016.cn\/wp-content\/uploads\/2026\/06\/ChatGPT-Image-2026\u5e746\u670824\u65e5-22_16_25-576x1024.png 576w, http:\/\/www.aimoli2016.cn\/wp-content\/uploads\/2026\/06\/ChatGPT-Image-2026\u5e746\u670824\u65e5-22_16_25-169x300.png 169w, http:\/\/www.aimoli2016.cn\/wp-content\/uploads\/2026\/06\/ChatGPT-Image-2026\u5e746\u670824\u65e5-22_16_25-768x1365.png 768w, http:\/\/www.aimoli2016.cn\/wp-content\/uploads\/2026\/06\/ChatGPT-Image-2026\u5e746\u670824\u65e5-22_16_25-864x1536.png 864w, http:\/\/www.aimoli2016.cn\/wp-content\/uploads\/2026\/06\/ChatGPT-Image-2026\u5e746\u670824\u65e5-22_16_25.png 941w\" sizes=\"auto, (max-width: 576px) 100vw, 576px\" \/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Q: Is well purging mandatory for field sampling? A: Yes. HJ 1019\u20142019 requires purging the well until water quality parameters stabilize or a specified volume of water is removed; additionally, disturbances such as air-lifting or aeration within the well must be avoided. Q: Should bailers be phased out? A: No. Standards still retain the bailer [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-618","post","type-post","status-publish","format-standard","hentry","category-blog"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.3 - aioseo.com -->\n\t<meta name=\"description\" content=\"Q: Is well purging mandatory for field sampling? A: Yes. HJ 1019\u20142019 requires purging the well until water quality parameters stabilize or a specified volume of water is removed; additionally, disturbances such as air-lifting or aeration within the well must be avoided. Q: Should bailers be phased out? A: No. Standards still retain the bailer\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Qingguo.Song\"\/>\n\t<link rel=\"canonical\" href=\"http:\/\/www.aimoli2016.cn\/?p=618\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.3\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Qingguo.Song Blog | AIMOLI Groundwater and Well Sampling\/Monitoring,Equipment,Microplastic Analysis\/detection\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Common questions regarding well purging before groundwater sampling | Qingguo.Song Blog\" \/>\n\t\t<meta property=\"og:description\" content=\"Q: Is well purging mandatory for field sampling? A: Yes. HJ 1019\u20142019 requires purging the well until water quality parameters stabilize or a specified volume of water is removed; additionally, disturbances such as air-lifting or aeration within the well must be avoided. Q: Should bailers be phased out? A: No. Standards still retain the bailer\" \/>\n\t\t<meta property=\"og:url\" content=\"http:\/\/www.aimoli2016.cn\/?p=618\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-09-28T23:12:31+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-09-28T23:12:32+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Common questions regarding well purging before groundwater sampling | Qingguo.Song Blog\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Q: Is well purging mandatory for field sampling? A: Yes. HJ 1019\u20142019 requires purging the well until water quality parameters stabilize or a specified volume of water is removed; additionally, disturbances such as air-lifting or aeration within the well must be avoided. Q: Should bailers be phased out? A: No. Standards still retain the bailer\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/?p=618#blogposting\",\"name\":\"Common questions regarding well purging before groundwater sampling | Qingguo.Song Blog\",\"headline\":\"Common questions regarding well purging before groundwater sampling\",\"author\":{\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/?author=1#author\"},\"publisher\":{\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"http:\\\/\\\/www.aimoli2016.cn\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/AIMOLI-Groundwater-Sampling-Equipment.png\",\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/?p=618\\\/#articleImage\",\"width\":1198,\"height\":1313,\"caption\":\"AIMOLI Groundwater Sampling Equipment\"},\"datePublished\":\"2026-09-29T07:12:31+08:00\",\"dateModified\":\"2026-09-29T07:12:32+08:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/?p=618#webpage\"},\"isPartOf\":{\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/?p=618#webpage\"},\"articleSection\":\"Blog\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/?p=618#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"http:\\\/\\\/www.aimoli2016.cn\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/?cat=1#listItem\",\"name\":\"Blog\"}},{\"@type\":\"ListItem\",\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/?cat=1#listItem\",\"position\":2,\"name\":\"Blog\",\"item\":\"http:\\\/\\\/www.aimoli2016.cn\\\/?cat=1\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/?p=618#listItem\",\"name\":\"Common questions regarding well purging before groundwater sampling\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/?p=618#listItem\",\"position\":3,\"name\":\"Common questions regarding well purging before groundwater sampling\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/?cat=1#listItem\",\"name\":\"Blog\"}}]},{\"@type\":\"Organization\",\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/#organization\",\"name\":\"Qingguo.Song Blog\",\"description\":\"AIMOLI Groundwater and Well Sampling\\\/Monitoring,Equipment,Microplastic Analysis\\\/detection\",\"url\":\"http:\\\/\\\/www.aimoli2016.cn\\\/\"},{\"@type\":\"Person\",\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/?author=1#author\",\"url\":\"http:\\\/\\\/www.aimoli2016.cn\\\/?author=1\",\"name\":\"Qingguo.Song\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/?p=618#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/36c1c527ac842b6790601f0083939bdcda187bbe9346c88f3ebe2ac6547e5783?s=96&d=identicon&r=g\",\"width\":96,\"height\":96,\"caption\":\"Qingguo.Song\"}},{\"@type\":\"WebPage\",\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/?p=618#webpage\",\"url\":\"http:\\\/\\\/www.aimoli2016.cn\\\/?p=618\",\"name\":\"Common questions regarding well purging before groundwater sampling | Qingguo.Song Blog\",\"description\":\"Q: Is well purging mandatory for field sampling? A: Yes. HJ 1019\\u20142019 requires purging the well until water quality parameters stabilize or a specified volume of water is removed; additionally, disturbances such as air-lifting or aeration within the well must be avoided. Q: Should bailers be phased out? A: No. Standards still retain the bailer\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/#website\"},\"breadcrumb\":{\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/?p=618#breadcrumblist\"},\"author\":{\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/?author=1#author\"},\"creator\":{\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/?author=1#author\"},\"datePublished\":\"2026-09-29T07:12:31+08:00\",\"dateModified\":\"2026-09-29T07:12:32+08:00\"},{\"@type\":\"WebSite\",\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/#website\",\"url\":\"http:\\\/\\\/www.aimoli2016.cn\\\/\",\"name\":\"Qingguo.Song Blog\",\"description\":\"AIMOLI Groundwater and Well Sampling\\\/Monitoring,Equipment,Microplastic Analysis\\\/detection\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"http:\\\/\\\/www.aimoli2016.cn\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Common questions regarding well purging before groundwater sampling | Qingguo.Song Blog","description":"Q: Is well purging mandatory for field sampling? A: Yes. HJ 1019\u20142019 requires purging the well until water quality parameters stabilize or a specified volume of water is removed; additionally, disturbances such as air-lifting or aeration within the well must be avoided. Q: Should bailers be phased out? A: No. Standards still retain the bailer","canonical_url":"http:\/\/www.aimoli2016.cn\/?p=618","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"http:\/\/www.aimoli2016.cn\/?p=618#blogposting","name":"Common questions regarding well purging before groundwater sampling | Qingguo.Song Blog","headline":"Common questions regarding well purging before groundwater sampling","author":{"@id":"http:\/\/www.aimoli2016.cn\/?author=1#author"},"publisher":{"@id":"http:\/\/www.aimoli2016.cn\/#organization"},"image":{"@type":"ImageObject","url":"http:\/\/www.aimoli2016.cn\/wp-content\/uploads\/2026\/07\/AIMOLI-Groundwater-Sampling-Equipment.png","@id":"http:\/\/www.aimoli2016.cn\/?p=618\/#articleImage","width":1198,"height":1313,"caption":"AIMOLI Groundwater Sampling Equipment"},"datePublished":"2026-09-29T07:12:31+08:00","dateModified":"2026-09-29T07:12:32+08:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"http:\/\/www.aimoli2016.cn\/?p=618#webpage"},"isPartOf":{"@id":"http:\/\/www.aimoli2016.cn\/?p=618#webpage"},"articleSection":"Blog"},{"@type":"BreadcrumbList","@id":"http:\/\/www.aimoli2016.cn\/?p=618#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"http:\/\/www.aimoli2016.cn\/#listItem","position":1,"name":"Home","item":"http:\/\/www.aimoli2016.cn\/","nextItem":{"@type":"ListItem","@id":"http:\/\/www.aimoli2016.cn\/?cat=1#listItem","name":"Blog"}},{"@type":"ListItem","@id":"http:\/\/www.aimoli2016.cn\/?cat=1#listItem","position":2,"name":"Blog","item":"http:\/\/www.aimoli2016.cn\/?cat=1","nextItem":{"@type":"ListItem","@id":"http:\/\/www.aimoli2016.cn\/?p=618#listItem","name":"Common questions regarding well purging before groundwater sampling"},"previousItem":{"@type":"ListItem","@id":"http:\/\/www.aimoli2016.cn\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"http:\/\/www.aimoli2016.cn\/?p=618#listItem","position":3,"name":"Common questions regarding well purging before groundwater sampling","previousItem":{"@type":"ListItem","@id":"http:\/\/www.aimoli2016.cn\/?cat=1#listItem","name":"Blog"}}]},{"@type":"Organization","@id":"http:\/\/www.aimoli2016.cn\/#organization","name":"Qingguo.Song Blog","description":"AIMOLI Groundwater and Well Sampling\/Monitoring,Equipment,Microplastic Analysis\/detection","url":"http:\/\/www.aimoli2016.cn\/"},{"@type":"Person","@id":"http:\/\/www.aimoli2016.cn\/?author=1#author","url":"http:\/\/www.aimoli2016.cn\/?author=1","name":"Qingguo.Song","image":{"@type":"ImageObject","@id":"http:\/\/www.aimoli2016.cn\/?p=618#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/36c1c527ac842b6790601f0083939bdcda187bbe9346c88f3ebe2ac6547e5783?s=96&d=identicon&r=g","width":96,"height":96,"caption":"Qingguo.Song"}},{"@type":"WebPage","@id":"http:\/\/www.aimoli2016.cn\/?p=618#webpage","url":"http:\/\/www.aimoli2016.cn\/?p=618","name":"Common questions regarding well purging before groundwater sampling | Qingguo.Song Blog","description":"Q: Is well purging mandatory for field sampling? A: Yes. HJ 1019\u20142019 requires purging the well until water quality parameters stabilize or a specified volume of water is removed; additionally, disturbances such as air-lifting or aeration within the well must be avoided. Q: Should bailers be phased out? A: No. Standards still retain the bailer","inLanguage":"en-US","isPartOf":{"@id":"http:\/\/www.aimoli2016.cn\/#website"},"breadcrumb":{"@id":"http:\/\/www.aimoli2016.cn\/?p=618#breadcrumblist"},"author":{"@id":"http:\/\/www.aimoli2016.cn\/?author=1#author"},"creator":{"@id":"http:\/\/www.aimoli2016.cn\/?author=1#author"},"datePublished":"2026-09-29T07:12:31+08:00","dateModified":"2026-09-29T07:12:32+08:00"},{"@type":"WebSite","@id":"http:\/\/www.aimoli2016.cn\/#website","url":"http:\/\/www.aimoli2016.cn\/","name":"Qingguo.Song Blog","description":"AIMOLI Groundwater and Well Sampling\/Monitoring,Equipment,Microplastic Analysis\/detection","inLanguage":"en-US","publisher":{"@id":"http:\/\/www.aimoli2016.cn\/#organization"}}]},"og:locale":"en_US","og:site_name":"Qingguo.Song Blog | AIMOLI Groundwater and Well Sampling\/Monitoring,Equipment,Microplastic Analysis\/detection","og:type":"article","og:title":"Common questions regarding well purging before groundwater sampling | Qingguo.Song Blog","og:description":"Q: Is well purging mandatory for field sampling? A: Yes. HJ 1019\u20142019 requires purging the well until water quality parameters stabilize or a specified volume of water is removed; additionally, disturbances such as air-lifting or aeration within the well must be avoided. Q: Should bailers be phased out? A: No. Standards still retain the bailer","og:url":"http:\/\/www.aimoli2016.cn\/?p=618","article:published_time":"2026-09-28T23:12:31+00:00","article:modified_time":"2026-09-28T23:12:32+00:00","twitter:card":"summary_large_image","twitter:title":"Common questions regarding well purging before groundwater sampling | Qingguo.Song Blog","twitter:description":"Q: Is well purging mandatory for field sampling? A: Yes. HJ 1019\u20142019 requires purging the well until water quality parameters stabilize or a specified volume of water is removed; additionally, disturbances such as air-lifting or aeration within the well must be avoided. Q: Should bailers be phased out? A: No. Standards still retain the bailer"},"aioseo_meta_data":{"post_id":"618","title":null,"description":null,"keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"limit_modified_date":false,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-09-28 23:12:32","updated":"2026-09-29 08:03:41","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"http:\/\/www.aimoli2016.cn\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"http:\/\/www.aimoli2016.cn\/?cat=1\" title=\"Blog\">Blog<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tCommon questions regarding well purging before groundwater sampling\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"http:\/\/www.aimoli2016.cn\/"},{"label":"Blog","link":"http:\/\/www.aimoli2016.cn\/?cat=1"},{"label":"Common questions regarding well purging before groundwater sampling","link":"http:\/\/www.aimoli2016.cn\/?p=618"}],"_links":{"self":[{"href":"http:\/\/www.aimoli2016.cn\/index.php?rest_route=\/wp\/v2\/posts\/618","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.aimoli2016.cn\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.aimoli2016.cn\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.aimoli2016.cn\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.aimoli2016.cn\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=618"}],"version-history":[{"count":1,"href":"http:\/\/www.aimoli2016.cn\/index.php?rest_route=\/wp\/v2\/posts\/618\/revisions"}],"predecessor-version":[{"id":619,"href":"http:\/\/www.aimoli2016.cn\/index.php?rest_route=\/wp\/v2\/posts\/618\/revisions\/619"}],"wp:attachment":[{"href":"http:\/\/www.aimoli2016.cn\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=618"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.aimoli2016.cn\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=618"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.aimoli2016.cn\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=618"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}